| Generator Specifications |
|
| Standby Output 150° Rise kVA/kW: |
|
| Single phase voltage @ 240V |
45/45 |
| 3 phase voltage @ 208V |
72/58 |
| 3 phase voltage @ 240V |
72/58 |
| 3 phase voltage @ 480V |
81/65 |
| Continuous Output 125° Rise kVA/kW: |
|
| Single phase voltage @ 240V |
43/43 |
| 3 phase voltage @ 208V |
69/55 |
| 3 phase voltage @ 240V |
69/55 |
| 3 phase voltage @ 480V |
75/60 |
| Amperage (Continuous) kVA/kW: |
|
| Single phase amperage @ 240V/120V |
179.2/358.3 |
| 3 phase amperage @ 208V |
190.8 |
| 3 phase amperage @ 240V |
165.4 |
| 3 phase amperage @ 480V |
90.2 |
| Voltage-3 phase adjustable |
208/220/240/416/440/460/480 |
| Voltage-Single phase adjustable |
120/127/139/240/254/277 |
| 3 phase power factor |
0.8 |
| Voltage regulation |
1/2% |
| Frequency |
50 or 60 Hertz |
| Total harmonic distortion |
< 5% |
| Insulation |
Class F |
| Engine Specifications |
|
| Manufacturer |
John Deere |
| Model |
TO4045T |
| Cylinders |
4 |
| Induction system |
Turbocharged |
| Displacement, L (cu. in.) |
4.5L (276) |
| HP @ rated speed |
100.0 |
| RPM |
1800 |
| Bore and stroke |
4.19" x 5.0" |
| Lubrication capacity (with filter) |
14 Qts |
| Battery recommendation min.(cold cranking amps) |
900 |
| - Battery rack and cable supplied (battery not included) |
| - Spin-on oil filter |
| - Thermostat controlled cooling system |
| - 12V engine alternator |
| - 12V starter motor |
| Receptacle Specifications |
|
| 120 Volt 20 Amp GFCI |
6 |
| 120/240 Volt CS6369 Twistlock |
3 |
| Two wire remote start capability |
Yes |
| Fuel System Specifications |
|
| Fuel consumption (GPH): |
|
| 1/2 load |
2.7 |
| Full load |
4.9 |
| Fuel |
Diesel |
| Approximate run time (Hours): |
|
| 1/2 load |
30 |
| Full load |
16 |
| Fuel Capacity (Gal.) |
80 |
| Weights and Dimensions |
|
| Weight without fuel |
3848 |
| Weight without fuel and without trailer |
3053 |
| Dimensions with trailer (L x W x H) |
147” x 60” x 81” |
| Dimensions without trailer (L x W x H) |
84” x 38” x 61” |
| Sound Level |
|
| Sound level dB(A) |
67 |
| 7 meters, full load |
|
| Engine, Generator Instrumentation |
|
| Voltmeter, ammeter, frequency meter, phase selector
switch, oil pressure gauge, water temperature gauge,
battery voltmeter, start/stop/auto switch, voltage
adjusting rheostat, elapsed time meter, individual
fault shutdown lights, panel lights with switch,
receptacle panel |