Baldor Mobile Power Generator Features

  • Brushless generator for long life, low maintenance
  • 3 position reconnection switch for easy voltage selection
  • Voltage Requlation 1/2%
  • Baldor control system: All operator controls are located behind one lockable panel door
  • Automatic safety shutdowns with indicator lights: low oil pressure, high water temp., engine overcrank, engine overspeed
  • Industrial grade, self-priming Isuzu engine
  • Illuminated instrumentation panel
  • 60 hertz frequency
  • Circuit breaker - main
  • Circuit breakers - outlets
  • Single point removable lifting eye
  • 6 bolts to remove generator from trailer
  • Cold start aid - glow plugs
  • Fuel/water seperator
  • Generator available with trailer
  • Automatic start feature (with optional transfer switch)
  • Lighted license plate bracket
  • Premium grade DOT approved tandem axle highway trailer featuring: torsion bar suspension (no more broken leaf springs), diamond plate aluminum fenders, leveling jack, running lights, surge brakes
  • Heavy gauge steel sound attenuated enclosure with muffler
  • Durable powder coat paint finish
  • Lockable door panels
  • Long run internal fuel tanks
  • Warranty:
    - limited 3 year warranty
    - 1 year or 3000 hours parts and labor
    - 3 year or 3000 hours parts
 
Options
  • Electronic governor
  • Electric brakes
  • Block heater
  • Battery charger
  • Ball hitch (3” pintle hitch standard)
  • Automatic transfer switches
  • Generator without trailer

Back to Top

 
Generator Specifications
Standby Output 150° Rise kVA/kW:
Single phase voltage @ 240V 43/43
3 phase voltage @ 208V 60/48
3 phase voltage @ 240V 61/49
3 phase voltage @ 480V 61/49
Continuous Output 125° Rise kVA/kW:
Single phase voltage @ 240V 40/40
3 phase voltage @ 208V 56/45
3 phase voltage @ 240V 56/45
3 phase voltage @ 480V 56/45
Amperage (Continuous) kVA/kW:
Single phase amperage @ 240V/120V 166/2x166
3 phase amperage @ 208V 155
3 phase amperage @ 240V 134
3 phase amperage @ 480V 67
Voltage-3 phase adjustable 208/220/240/416/440/460/480
Voltage-Single phase adjustable 120/127/139/240/254/277
3 phase power factor
0.8
Voltage regulation 1/2%
Frequency 60 Hertz
Total harmonic distortion < 5%
Insulation Class H
Engine Specifications
Manufacturer John Deere
Model 5030TF270
Cylinders 5
Induction system Turbocharged
Displacement, L (cu. in.) 3.0L (186)
EPA Emissions Level Tier 2
HP @ rated speed 80
RPM 1800
Bore and stroke 3.4" x 4.1"
Lubrication capacity (with filter) 11.8 Qts
Battery recommendation min.(cold cranking amps) 925
  - Battery rack and cable supplied (battery not included)
  - Spin-on oil filter
  - Thermostat controlled cooling system
  - 12V engine alternator
  - 12V starter motor
Receptacle Specifications
120 Volt 20 Amp GFCI
23
120/240 Volt CS6369 Twistlock
3
Two wire remote start capability Yes
Fuel System Specifications
Fuel Consumption Standby Rating (GPH):
1/2 load
2.2
Full load
4.4
Approximate Run Time Standby Rating (Hours):
1/2 load
36
Full load
18
Fuel Capacity:  
Fuel Diesel
Galllons
80
Weights and Dimensions
Weight without fuel
4040
Weight without fuel and without trailer
3215
Dimensions with trailer (L x W x H) 147” x 62” x 85”
Dimensions without trailer (L x W x H) 84" x 38" x 61"
Sound Level
Sound level dB(A)
67
7 meters, full load
Engine, Generator Instrumentation
Voltmeter, ammeter, frequency meter, phase selector switch, oil pressure gauge, water temperature gauge, battery voltmeter, start/stop/auto switch, voltage adjusting rheostat, elapsed time meter, individual fault shutdown lights, panel lights with switch, receptacle panel

WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.
 